DC Inverter Water to Water Heat Pump

Model

AHP-12W/W

AHP-24W/W

Refrigerant

 

R410A

Power Supply

 

220-240V/50Hz/1Ph

Compressor

 

DC Inverter Rotary

Twin Rotary

Water-loop Rating Conditions

 

Nominal Cooling Capacity

Btu/h

3400-14500

8100-26500

W

1000-4200

2300-7800

Nominal Heating Capacity

Btu/h

4000-18000

11000-30000

W

1200-5300

3200-8800

Input Power (Cooling)

W

460-1500

1200-3500

Input Power (Heating)

W

510-1750

1100-3000

Input Current (Cooling)

A

2.1-6.7

5.1-15.5

Input Current (Heating)

A

2.3-7.8

4.9-13.5

E.E.R

Btu/h.W

7.8-12.5

7.4-11

C.O.P

W/W

2.0-4.0

2.5-3.7

User Side

 

Heat Exchanger

 

High Efficiency Tube in Shell

High Efficiency Tube in Shell

Input Power of  Water Pump

W

95

175

Max. Water  Head                     

m

6

6

Max. Water Flow          

m3/h

0.65

1.3

Water Pressure Drop

kPa

6

6

Connection Pipe

Inch

G3/4

G3/4

Source Side

 

Heat Exchanger

 

High Efficiency Tube in Shell

High Efficiency Tube in Shell

Input Power of Water Pump

W

95

175

Max. Water  Head                     

m

6

6

Max. Water  Flow          

m3/h

0.8

1.6

Water Pressure Drop

kPa

6

10

Connection Pipe

Inch

G3/4

G3/4

Noise Level

dB(A)

40

40

Net Dimension(L×D×H)

mm

500×370×540

670×470×650

Packing Dimension(L×D×H)

mm

592×380×595

720×520×700

Net  Weight

Kg

49

50

Shipping  Weight

Kg

54

55

 

 

Test conditions:

 

Mode

Rating Conditions

Indoor heat exchanger   (Inlet/Outlet) °C

Outdoor heat exchanger      (Inlet/Outlet) °C

Cooling

Water-loop

12/7

30/35

Heating

Water-loop

30/35

10/-